Q
Соглашение об уровне обслуживания

Аптайм 99.982% Гарантировано

Корпоративная надёжность, подкреплённая контрактными SLA-кредитами. Наш Tier III TIA-942 объект обеспечивает стабильную производительность.

Uptime Commitment

99.982%
Monthly Uptime SLA
Tier III TIA-942 standard
<10min
Incident Response
24/7/365 NOC monitoring
2N
Full Redundancy
Power, cooling, network

What 99.982% Uptime Means

~1.6 hours
Max downtime per year
~7.9 min
Max downtime per month
~1.8 min
Max downtime per week

SLA Credit Schedule

If we fail to meet our SLA, you receive automatic service credits. No claim forms needed.

Monthly UptimeDowntimeService CreditApplied To
99.982% — 99.9%< 43 min0%No credit
99.9% — 99.5%43 min — 3.6 hrs10%Next month invoice
99.5% — 99.0%3.6 hrs — 7.3 hrs25%Next month invoice
99.0% — 95.0%7.3 hrs — 36.5 hrs50%Next month invoice
Below 95.0%> 36.5 hrs100%Full month refund

Service-Specific SLAs

GPU Cloud

NVIDIA Rubin R100 NVL72

Uptime SLA99.982%
Provisioning Time< 15 minutes
Network Latency (intra-rack)< 1 µs
Storage IOPS100K+ random read
Data Durability99.999%
Maintenance WindowTue 02:00-06:00 UTC
Groq LPX Inference

Real-Time Inference API

API Uptime99.95%
P50 Latency< 8ms
P99 Latency< 25ms
Rate Limit1,000 req/min
Error Rate Target< 0.1%
Support Response< 1 hour (P1)

Support Response Times

PriorityDescriptionResponse TimeResolution Target
P1 — CriticalService down, all users affected< 15 min< 1 hour
P2 — HighMajor feature degraded< 30 min< 4 hours
P3 — MediumMinor impact, workaround exists< 2 hours< 24 hours
P4 — LowGeneral inquiry, feature request< 8 hours< 5 business days

Infrastructure Guarantees

Power Redundancy

3×5MW Jichai gas generators. 2N UPS. 800VDC distribution. No single point of failure.

❄️

Cooling Redundancy

2×8MW ABHM Shuangliang absorption chillers. CDU liquid cooling per rack. N+1 configuration.

🌐

Network Redundancy

Dual uplinks from Tier 1 carriers. InfiniBand Quantum-X800 with redundant fabric managers.

🔒

Physical Security

Biometric access control. 24/7 security guards. CCTV with 90-day retention. Mantrap entry.

🔥

Fire Suppression

FM-200 gas suppression. VESDA early smoke detection. Zoned protection per rack row.

🛡️

Data Protection

Encrypted at rest (AES-256) and in transit (TLS 1.3). Isolated VLAN per client. Daily backups.

SLA Exclusions

The following are excluded from SLA uptime calculations:

  • Scheduled maintenance windows (communicated 72 hours in advance)
  • Force majeure events (natural disasters, government actions)
  • Client-caused incidents (misconfiguration, exceeding quotas)
  • Third-party service outages outside Qube Compute control
  • Beta or preview services explicitly marked as non-SLA

Legal Framework: This SLA is governed by AIFC English Common Law. Disputes resolved through IAC (International Arbitration Centre) arbitration. Full SLA terms are included in the Master Service Agreement.

Вопросы о нашем SLA?

Запросите копию полного Мастер-соглашения или запланируйте звонок с нашей инфраструктурной командой.